Fire Suppression Systems – Which ones right for you ?
When you need a fire suppression system for your Server Room, Data Centre, Switch Room, or indeed any business-critical area.
But are unsure which one suits you best ?? Inert Fire suppression system – Inergen, Chemical Based – Novec 1230, Water mist, Carbon Dioxide (CO2). Aerosol Fire Suppression.
Fortunately Aspect Fire Solutions, with over 20 years experience can discuss and choose with you the right extinguishing solution to meet your needs.
We offer all of the above fire suppression systems.
We Design, Install, Commission and service them with the skill and diligence you would expect from a company that holds BAFE SP203 & LPS 1204 Approvals for gaseous fire suppression systems.
Once installed we can offer you 24/7 service and maintenance to keep your system working to its optimum throughout its life.
So, feel free contact us to discuss your fire suppression system.



RETROTEC TRAINING DAY
Retrotec Training Day at Aspect Fire
A day of hands-on learning and practical insight at our offices today for Jacob Taylor.
Jacob spent the day diving into the essentials of Retrotec door fan testing, focusing on how to accurately measure room integrity and ensure fire suppression systems perform as designed when it matters most.
What we covered:
Principles of room integrity testing (RIT)
Setting up Retrotec door fan systems
Measuring air leakage and calculating equivalent leakage area (ELA)
Understanding hold time requirements for gaseous suppression systems
Identifying and rectifying common leakage paths
Interpreting test results in line with industry standards
Effective Retrotec testing ensures that protected enclosures can maintain the required concentration of extinguishing agent—critical for compliance, system performance, and ultimately, life safety.
Building knowledge, sharpening skills, and reinforcing our commitment to delivering high-quality fire protection solutions.
ANSUL R102
FROM Schools to Supermarkets, Café’s to Colleges………
These are just a few of the wide-ranging customers we have carried out ANSUL R102 Installation works for this month.
We are experts in designing and installing ANSUL R102 Systems ….. don’t just take our word for it …… we are holders of the prestigious BAFE SP206 Accreditation for the design, installation and servicing of Kitchen Fire Suppression systems.
We have our own in house, design, installation, and servicing teams. All ANSUL R102 Trained and certified.
So, if it’s a new install, modifications to existing or Service and maintenance of you ANSUL R102 Kitchen Fire Suppression System. ……… Then please get in touch for impartial advice and free quotations………
Please get in touch today to discuss your requirements.
For further information see link below.
FM200 – INERGEN – ARGONITE – NOVEC – CO2 – ANSUL R102
What do they all have in common ??
They all need 10-year hydrostatic testing.
This is a pressure vessels regulation and is MANDATORY.
The cylinders must be taken away, by ADR Transport, de -pressurised, stripped, inspected, pressure tested, re-assembled, refilled and then transported by ADR Transport back to you.
Sound likes a right Faff !!
We offer a service exchange facility to cut out “downtime” and all the hassle.
We can provide service exchange cylinders; they have been tested and certified for a further 10 years.
Our F-GAS Trained engineer’s will attend site, install the service exchange cylinders, and supervise the removal onto ADR Transport of your existing cylinders. Giving you continuous protection for your system….. WITHOUT the faff !!
Just what you would expect from an LPS 1204 & BAFE SP203 Company.
Please get in touch today to discuss your requirements.
For further information see link below.
https://aspect-fire-suppression.co.uk/wp-content/uploads/2018/11/FIA-Fire-Industry-Association.pdf